Communication Format
Data is transferred from the meter through a serial communication channel.
In serial communications, the voltage is switched between a high and low level
at a predetermined rate (baud rate) using ASCII encoding. The receiving device
reads the voltage levels at the same intervals and then translates the switched
levels back to a character.
The voltage level conventions depend on the interface standard. The table
lists the voltage levels for each standard.
Start bit
IDLE
IDLE
0 b 0 b 1 b 2 b 3 b 4 b 5 b 6 b 7 1
(8 data, no parity, 1 stop)
0 b 0 b 1 b 2 b 3 b 4 b 5 b 6 P 1
(7 data, parity, 1 stop)
Stop bit
IDLE
IDLE
LOGIC
1
0
INTERFACE STATE
mark (idle)
space (active)
RS232*
TXD,RXD; -3 to -15 V
TXD,RXD; +3 to +15 V
RS485*
a-b < -200 mV
a-b > +200 mV
IDLE
0 b 0 b 1 b 2 b 3 b 4 b 5 b 6 1 1
(7 data, no parity, 2 stop)
Note: b 0 - b 7 is ASCII data.
IDLE
* Voltage levels at the Receiver
Data is transmitted one byte at a time with a variable idle period between
characters (0 to ∞ ). Each ASCII character is “framed” with a beginning start bit,
an optional error detection parity bit and one or more ending stop bits. The data
format and baud rate must match that of other equipment in order for
communication to take place. The figures list the data formats employed by
the meter.
Start bit and Data bits
Data transmission always begins with the start bit. The start bit signals the
receiving device to prepare for reception of data. One bit period later, the least
significant bit of the ASCII encoded character is transmitted, followed by the
remaining data bits. The receiving device then reads each bit position as they are
transmitted. Since the sending and receiving devices operate at the same
transmission speed (baud rate), the data is read without timing errors.
Character Frame Figure
Parity bit
After the data bits, the parity bit is sent. The transmitter sets the parity bit to
a zero or a one, so that the total number of ones contained in the transmission
(including the parity bit) is either even or odd. This bit is used by the receiver
to detect errors that may occur to an odd number of bits in the transmission.
However, a single parity bit cannot detect errors that may occur to an even
number of bits. Given this limitation, the parity bit is often ignored by the
receiving device. The PAX meter ignores the parity bit of incoming data and
sets the parity bit to odd, even or none (mark parity) for outgoing data.
Stop bit
The last character transmitted is the stop bit. The stop bit provides a single bit
period pause to allow the receiver to prepare to re-synchronize to the start of a
new transmission (start bit of next byte). The receiver then continuously looks
for the occurrence of the start bit.
6.8 MODULE 8 - A NALOG O UTPUT P ARAMETERS ( ????? ) ?
8-Out
PAR
PARAMETER MENU
PAXT
ONLY
Pro
tYPE
Analog
Type
ASIN
Analog
Assignment
AN-LO
Analog Low
Scale Value
AN-HI
Analog High
Scale Value
udt
Analog
Update Time
burn
Burn-out
Action
? - An analog output card must be installed in order to access this
module.
ANALOG HIGH SCALE VALUE
???? ?
? ????
ANALOG TYPE
SELECTION RANGE
???? 0 to 20 mA
???? 4 to 20 mA
????? ?
? ??????
?????? to ?????
Enter the Display Value that corresponds to 20 mA (0-20
mA) , 20 mA (4-20 mA) or 10 VDC (0-10 VDC).
???? 0 to 10 V
Enter the analog output type. For 0-20 mA or 4-20 mA
use terminals 18 and 19. For 0-10 V use terminals 16 and
17. Only one range can be used at a time.
ANALOG ASSIGNMENT
?
??? ?
???
ANALOG UPDATE TIME
??? to ????
Enter the analog output update rate in seconds. A value
of 0.0 allows the meter to update the analog output at a
rate of 20/sec.
???? ?
?
??
???? ?
? ???
??? ?? ?? ???
Enter the source for the analog output to retransmit:
??? = Display Input Value
?? = Maximum Display Input Value
?? = Minimum Display Input Value
??? = Totalize Display Value
ANALOG LOW SCALE VALUE
PROBE BURN-OUT ACTION (PAXT ONLY)
?? ??
Enter the probe burn-out action. In the event of a
temperature probe failure, the analog output can be
programmed for low or high scale.
????? ?
??????
to
?????
?
????
Enter the Display Value that corresponds to 0 mA (0-20
mA) , 4 mA (4-20 mA) or 0 VDC (0-10 VDC).
28
相关PDF资料
PB-1583-TF BOX ABS 4.37X3.12X2" BK 1=10PCS
PB-1583 BOX ABS 4.37X3.12X2" BK 1=10PCS
PBS-11273 BOX ABS 6.30" X 3.75" X 1.41" BK
PBS-11275 BOX ABS 6.30" X 3.75" X 1.41" BK
PBS-11294-G BOX 5.62" X 3.25" X 1.5" GRAY
PBS-11327-B BOX 5.62" X 3.25" X 1.5" BLACK
PBS-11532-B BOX 4.37" X 3.25" X 1.52" BLACK
PBS-12631AV2G SWITCH PUSHBUTTON SPDT 6A 125V
相关代理商/技术参数
PAXTM110 制造商:Red Lion Controls 功能描述:TIMER, FIELD UPGRADEABLE GREEN DC 制造商:Red Lion Controls 功能描述:DC TIMER FIELD GREEN
PAXUSB00 制造商:Red Lion Controls 功能描述:USB PROGRAMMING CARD FOR PAX SERIES 制造商:Red Lion Controls 功能描述:USB OPTION CARD
PAY23015A12 功能描述:硬公制连接器 LOCKING PIN ASSEMBLY RoHS:否 制造商:TE Connectivity / AMP 系列:Z-Pack 产品类型:Receptacles 排数:5 位置/触点数量:110 安装角:Right 端接类型:Pin 外壳材料:Polyester 触点材料:Phosphor Bronze 触点电镀:Gold 类型:
PAY23015A1A1 功能描述:硬公制连接器 GRIP FINGER RoHS:否 制造商:TE Connectivity / AMP 系列:Z-Pack 产品类型:Receptacles 排数:5 位置/触点数量:110 安装角:Right 端接类型:Pin 外壳材料:Polyester 触点材料:Phosphor Bronze 触点电镀:Gold 类型:
PAY245A10 功能描述:手工工具 HM2 CONTACT EXTR TOOL-LONG PINS RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A106 功能描述:手工工具 RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A11 功能描述:手工工具 HM2 CONTACT EXTR TOOL-SHORT PINS RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A112 功能描述:手工工具 INSERT BLOCK RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool